3. During the Filter press process, the operator should monitor the working conditions of the filter press in time; after reaching the rated pressure, if the flow rate of the liquid outlet is found to be very small, the feeding should be stopped immediately and the feeding valve should be closed, and the unloading can be started after a short stop . If the filter cloth is found to be dirty, it can be washed with a high-pressure water gun. When cleaning the filter cloth, the water gun should be cleaned from the filter cloth to the outside. If it cannot be completely cleaned with a high-pressure water gun, it must be removed for immersion cleaning (we mentioned how to clean the filter cloth earlier). After cleaning, the filter cloth should be turned over and closed for next cycle.